Plumbing, Heating, and Cooling in Birmingham, MI

 static image family hugging on couchIf you need plumbing, heating, or cooling service in Birmingham, MI, trust the team with the experience to get the job done right — Matheson Heating, Air, and Plumbing.

At Matheson, we’ve been in business since 1946, piloting your home to flawless function and comfort. Our mission has always been to service every customer with distinction, ensuring your access to clean, hot, and cold water, along with temperature controls to beat the heat and stay cozy in the winter.

Whether you want high-efficiency systems to help cut your monthly utility costs or you need updates for aging infrastructure, our team is fully stocked, ready to launch, and highly trained in their area of expertise.

Birmingham’s Top Plumbing Company

Leaking pipeWhen you’ve been around for more than 75 years, you learn a thing or two. Here at Matheson, we’ve learned how to keep your plumbing in tip-top shape without handing you an unreasonable bill. Our plumbing experts are all licensed and insured because we believe that you should have peace of mind when it comes to home repairs. Our plumbers don’t just settle for the fastest fix. Instead, we take the time to get to the bottom of every issue and make recommendations that will leave your home in good condition for decades to come.

From water heater upgrades to repiping services, we do it all. If you want to add a bathroom, we’ll help you with the practical plumbing issues and the finishing touches that turn the space into a peaceful oasis. Our team also specializes in water treatment services, so you can improve both the delivery system and the quality of water in your home. With Birmingham’s hard water, it’s a good idea to focus on both types of systems for the biggest boost in home comfort.

We offer a great selection of reliable HVAC services!
  • Plumbing repairs
  • Drain service
  • Tankless water heaters
  • Gas lines
  • Plumbing installation
  • Sump pumps
  • Water filtration and softeners

Reliable Heating and Cooling Service in Birmingham

Furnace and ACBirmingham winters get cold, icy, and snowy, which means you need reliable heat that works when you turn it on. With help from Matheson, that’s exactly what you get — functional heat even in the worst weather. While we’re all about offering energy-efficient solutions to help cut your heating costs, our main focus is on reliability to help you avoid heating loss during the coldest months of the year.

Did you know that the average family spends 42% of their gas and electric bill on heating? With our upgrade options, you can cut that number down to size. Some of the most energy-efficient gas furnaces offer nearly 100% efficiency, while geothermal heating solutions can produce heat at near zero energy.

While the cold weather of winter puts heat at the top of the list for home comfort and safety, we also install, maintain, and repair cooling systems. From heat pumps that do both heating and cooling to central cooling solutions, we handle everything. There’s no reason to sweat it out in the summer when you can come home to comfort. Plus, we install indoor air quality systems that help control humidity and reduce the spread of pollution and germs.

No matter what HVAC service you need, you can count on Matheson Heating, Air, and Plumbing!

When you need help with heating, cooling, or plumbing in Birmingham, reach out to Matheson Heating, Air, and Plumbing for fast, reliable service. We’ll install, maintain, or fix your system, guaranteed!

$150 Off

$150 Off AC or Furnace Surge Protector

Save $150 each on an AC surge protector or a furnace surge protector.

Mention this online offer when you contact us. Cannot be combined with any other offer.

Top-Flight Connection

Book Your Mission Planning Session Now!

Get ready for in depth mission planning for comfort superiority.

Book Online

Recent Jobs and Reviews in Birmingham, MI

Rated 5.0 out of 5 stars based on 1 customer reviews

Customers say: The overall sentiment across these reviews is overwhelmingly positive, reflecting strong customer satisfaction and trust in the company's services. Customers consistently praise the professionalism, efficiency, and expertise of the technicians, highlighting their punctuality, thoroughness, and ability to complete work quickly and effectively. A recurring theme is the exceptional customer service provided, with reviewers frequently noting how friendly, knowledgeable, and personable the staff members are. Many customers express appreciation for clear communication, honest assessments, and technicians who take time to explain procedures and answer questions thoughtfully. The company's reliability and integrity stand out as significant strengths, with several customers mentioning long-term relationships spanning years or even over a decade. Positive remarks about fair pricing, competitive rates, and no-pressure sales approaches further reinforce the favorable impression. Customers also value the company's responsiveness, with multiple mentions of quick service, small arrival windows, and efficient problem resolution. The installation teams receive particular commendation for being hardworking, respectful, and willing to go above and beyond expectations. Overall, the reviews convey a tone of genuine gratitude and confidence, with many customers explicitly stating they would recommend the company and plan to use their services again in the future.

Birmingham, MI at a glance

Matheson Heating Air Plumbing has completed 10 jobs in Birmingham, MI between July 2026 and September 2026.

The one customer review shown here is rated 5.0 out of 5.

The most recent job was on September 3, 2026.

Job Locations and Reviews

Review
Have used Matheson for many years - wouldn't think if using anyone else - when service is always exceptional, why go anywhere else!
Marianne - Birmingham, MI 48009
Birmingham, MI - Furnace tuneup
Safety, mechanical and performance systems were all tested, cleaned and maintained. Air filter and humidifier pad were changed. Combustion analysis and gas pressure testing show that the system is operating normally at this time and the thermostat is also operating normally at this time.
Samuel K.
Samuel K. Checked in
Furnace tuneup Safety, mechanical and performance systems were all tested, cleaned and maintained. Air filter and humidifier pad were changed. Combustion analysis and gas pressure testing show that the system is operating normally at this time and the thermostat is also operating normally at this time.
Birmingham, MI 48009
8-21-26

Found a fault with one of the zone dampers back feeding power. I also found the system low on refrigerant and I scheduled an installation team to come back and make that repair. I will return after ordering the proper damper to replace it.

8-26-26

Returned to replace faulty zone damper. Tested functionality and everything is working properly now.

10x10 slip damper (warranty)
8-21-26

Found a fault with one of the zone dampers back feeding power. I also found the system low on refrigerant and I scheduled an installation team to come back and make that repair. I will return after ordering the proper damper to replace it.

8-26-26

Returned to replace faulty zone damper. Tested functionality and everything is working properly now.

10x10 slip damper (warranty)
Kevin M.
Kevin M. Checked in
8-21-26 Found a fault with one of the zone dampers back feeding power. I also found the system low on refrigerant and I scheduled an installation team to come back and make that repair. I will return after ordering the proper damper to replace it. 8-26-26 Returned to replace faulty zone damper. Tested functionality and everything is working properly now. 10x10 slip damper (warranty)
Birmingham, MI 48009
Heating Systems

All three furnace systems received a complete tune-up, with the safety, mechanical, and performance components inspected and tested. Combustion analysis and gas pressures were tested and verified to be operating within the appropriate manufacturer specifications. Electrical connections and components were examined and tightened as needed throughout the indoor portions of all three systems. Overall, all three heating systems are operating normally at this time.

Cooling Systems

All three air-conditioning systems received a complete tune-up, with the safety, mechanical, and performance components inspected and tested. Cooling capacity was checked and all three systems are performing within manufacturer expectations. Electrical components and connections were examined and tightened at both the indoor and outdoor portions of all three systems. Overall, all three cooling systems are operating normally at this time.

Recommendations

Surge protection is recommended for both
Heating Systems

All three furnace systems received a complete tune-up, with the safety, mechanical, and performance components inspected and tested. Combustion analysis and gas pressures were tested and verified to be operating within the appropriate manufacturer specifications. Electrical connections and components were examined and tightened as needed throughout the indoor portions of all three systems. Overall, all three heating systems are operating normally at this time.

Cooling Systems

All three air-conditioning systems received a complete tune-up, with the safety, mechanical, and performance components inspected and tested. Cooling capacity was checked and all three systems are performing within manufacturer expectations. Electrical components and connections were examined and tightened at both the indoor and outdoor portions of all three systems. Overall, all three cooling systems are operating normally at this time.

Recommendations

Surge protection is recommended for both
Samuel K.
Samuel K. Checked in
Heating Systems All three furnace systems received a complete tune-up, with the safety, mechanical, and performance components inspected and tested. Combustion analysis and gas pressures were tested and verified to be operating within the appropriate manufacturer specifications. Electrical connections and components were examined and tightened as needed throughout the indoor portions of all three systems. Overall, all three heating systems are operating normally at this time. Cooling Systems All three air-conditioning systems received a complete tune-up, with the safety, mechanical, and performance components inspected and tested. Cooling capacity was checked and all three systems are performing within manufacturer expectations. Electrical components and connections were examined and tightened at both the indoor and outdoor portions of all three systems. Overall, all three cooling systems are operating normally at this time. Recommendations Surge protection is recommended for both
Birmingham, MI 48009
Trevor N.
Trevor N. Checked in
WO-TNFR711917 Arrived at the customer’s home regarding a gurgling sound in the guest bathroom when the toilet is flushed. This may indicate an issue with the main drain line or venting system. Referral was given. The second bathroom had a slow-draining sink. Reviewed the available options with the customer, and she elected to attempt to clear the obstruction. Removed the P-trap and pop-up assembly and found a significant amount of hair buildup in the pop-up assembly. Snaked the drain and successfully cleared the obstruction. Ran water for approximately 10 minutes to verify the drain was clear and flowing properly. Everything is functioning as it should at this time. No warranty provided on the drain cleaning.
Birmingham, MI 48009
Arrived to investigate 
Found unit from 2000.
Checked blower cap found a 5mfd wired in, I’ve googled the make and model and found it should have a 12.5 mfd capacitor. There is one that tests ok in the spot for the original capacitors mount?
-found filter backwards 
-blower wheel dirty 
-adjusted some dampers on runs.
-with the step up in power for the blower and no air restriction, the over condensation will cease. I would like to schedule a follow up for a project supervisor to go over options for replacement.
Scheduled next day 2-4 pm
Arrived to investigate 
Found unit from 2000.
Checked blower cap found a 5mfd wired in, I’ve googled the make and model and found it should have a 12.5 mfd capacitor. There is one that tests ok in the spot for the original capacitors mount?
-found filter backwards 
-blower wheel dirty 
-adjusted some dampers on runs.
-with the step up in power for the blower and no air restriction, the over condensation will cease. I would like to schedule a follow up for a project supervisor to go over options for replacement.
Scheduled next day 2-4 pm
Devin P.
Devin P. Checked in
Arrived to investigate Found unit from 2000. Checked blower cap found a 5mfd wired in, I’ve googled the make and model and found it should have a 12.5 mfd capacitor. There is one that tests ok in the spot for the original capacitors mount? -found filter backwards -blower wheel dirty -adjusted some dampers on runs. -with the step up in power for the blower and no air restriction, the over condensation will cease. I would like to schedule a follow up for a project supervisor to go over options for replacement. Scheduled next day 2-4 pm
Birmingham, MI 48009

Upon arrival furnace blower unit is operating but no old air blowing

Upon investigation of furnace unit found water all over the floor, 
Removed evaporator cover and it was all frozen inside - see picture.

Unable to troubleshoot at this time. Coil must defrost about 24 hrs

Unit with an water problem:
Evaporator Coil - CVAVA4821XMAEAAA
Furnace - 59TP6B100V211120
AC Condenser - 26SPA648W0030001

 Will need to reschedule visit

2 zoned system freezing up->
Verified zone system functionality, system has two thermostats and 4 4 valves.
2of which I didn’t record moving when I’ve activated their thermostats, upon further inspection I’ve found one with wiring that doesn’t match the others, fixed this and 2 more valves sprung to life.
-filter is not very old, but is fairly plugged.
-set blower speed it would appear that the furnace thought that the AC was two stage, it is not, set both speeds at the same speed for staging so it is irrelevant.
-in summary, there was a restriction in air deli

Upon arrival furnace blower unit is operating but no old air blowing

Upon investigation of furnace unit found water all over the floor, 
Removed evaporator cover and it was all frozen inside - see picture.

Unable to troubleshoot at this time. Coil must defrost about 24 hrs

Unit with an water problem:
Evaporator Coil - CVAVA4821XMAEAAA
Furnace - 59TP6B100V211120
AC Condenser - 26SPA648W0030001

 Will need to reschedule visit

2 zoned system freezing up->
Verified zone system functionality, system has two thermostats and 4 4 valves.
2of which I didn’t record moving when I’ve activated their thermostats, upon further inspection I’ve found one with wiring that doesn’t match the others, fixed this and 2 more valves sprung to life.
-filter is not very old, but is fairly plugged.
-set blower speed it would appear that the furnace thought that the AC was two stage, it is not, set both speeds at the same speed for staging so it is irrelevant.
-in summary, there was a restriction in air deli
Devin P.
Devin P. Checked in
Upon arrival furnace blower unit is operating but no old air blowing Upon investigation of furnace unit found water all over the floor, Removed evaporator cover and it was all frozen inside - see picture. Unable to troubleshoot at this time. Coil must defrost about 24 hrs Unit with an water problem: Evaporator Coil - CVAVA4821XMAEAAA Furnace - 59TP6B100V211120 AC Condenser - 26SPA648W0030001 Will need to reschedule visit 2 zoned system freezing up-> Verified zone system functionality, system has two thermostats and 4 4 valves. 2of which I didn’t record moving when I’ve activated their thermostats, upon further inspection I’ve found one with wiring that doesn’t match the others, fixed this and 2 more valves sprung to life. -filter is not very old, but is fairly plugged. -set blower speed it would appear that the furnace thought that the AC was two stage, it is not, set both speeds at the same speed for staging so it is irrelevant. -in summary, there was a restriction in air deli
Birmingham, MI 48009
Top Rank Air Conditioning Tune-Up

System One — Indoor Unit

* Evaporator coil was cleaned and examined.
* Evaporator drain was cleaned and verified.
* Air filter was changed.
* Thermostat was tested and is operating normally during the cooling load.
* Temperature differential between the supply and return air is 22°F.

System Two — Indoor Unit

* Evaporator coil was cleaned and examined.
* Evaporator drain was cleaned and verified.
* Air filter was changed.
* Thermostat was tested and is operating normally during the cooling load.
* Temperature differential between the supply and return air is 20°F.

System One — Outdoor Unit

* Condenser coil was cleaned and examined.
* Electrical connections were tightened.
* Infinity model does not use a conventional capacitor or contactor; therefore, these components are not applicable for testing.
* Electrical cabinet was cleaned and inspected.

System Two — Outdoor Unit

* Condenser coil was cleaned and examined.
* Electrical connections were ti
Top Rank Air Conditioning Tune-Up

System One — Indoor Unit

* Evaporator coil was cleaned and examined.
* Evaporator drain was cleaned and verified.
* Air filter was changed.
* Thermostat was tested and is operating normally during the cooling load.
* Temperature differential between the supply and return air is 22°F.

System Two — Indoor Unit

* Evaporator coil was cleaned and examined.
* Evaporator drain was cleaned and verified.
* Air filter was changed.
* Thermostat was tested and is operating normally during the cooling load.
* Temperature differential between the supply and return air is 20°F.

System One — Outdoor Unit

* Condenser coil was cleaned and examined.
* Electrical connections were tightened.
* Infinity model does not use a conventional capacitor or contactor; therefore, these components are not applicable for testing.
* Electrical cabinet was cleaned and inspected.

System Two — Outdoor Unit

* Condenser coil was cleaned and examined.
* Electrical connections were ti
Samuel K.
Samuel K. Checked in
Top Rank Air Conditioning Tune-Up System One — Indoor Unit * Evaporator coil was cleaned and examined. * Evaporator drain was cleaned and verified. * Air filter was changed. * Thermostat was tested and is operating normally during the cooling load. * Temperature differential between the supply and return air is 22°F. System Two — Indoor Unit * Evaporator coil was cleaned and examined. * Evaporator drain was cleaned and verified. * Air filter was changed. * Thermostat was tested and is operating normally during the cooling load. * Temperature differential between the supply and return air is 20°F. System One — Outdoor Unit * Condenser coil was cleaned and examined. * Electrical connections were tightened. * Infinity model does not use a conventional capacitor or contactor; therefore, these components are not applicable for testing. * Electrical cabinet was cleaned and inspected. System Two — Outdoor Unit * Condenser coil was cleaned and examined. * Electrical connections were ti
Birmingham, MI 48009
Kevin M.
Kevin M. Checked in
5-14-26 Unico System Diagnostic Report Customer Concern • Homeowner stated the Unico system installed approximately three years ago was not cooling properly. Diagnostic Findings • Verified the indoor and outdoor equipment were receiving proper voltage and power supply. • Found a low-pressure fault code stored at the outdoor condensing unit. • Connected refrigerant gauges and confirmed the system was extremely low on refrigerant. • Charged the system back to manufacturer specifications to restore proper operation. • Performed a visual refrigerant leak inspection at all accessible joints and fittings. • Applied soap solution leak detection spray to all accessible refrigerant joints and connections in an attempt to locate the refrigerant leak. • Inspected the outdoor condenser, compressor area, and accessible refrigerant piping for
Birmingham, MI 48009
Birmingham, MI - Drained and flushed boiler and Hartford loop
Removed and cleaned sight glass
Removed and cleaned low water cut off
Flushed pigtail
Sight glass show corrosion, nuts show corrosion, rubber gaskets show deterioration 
Drain boiler tank valve hard to open/close. 
Reset water feeder to 000
Checked heat via infrared - Trevor
Doughter room is not heating
Dining room not heating 

Customer did not go with repair
Norbert A.
Norbert A. Checked in
Drained and flushed boiler and Hartford loop Removed and cleaned sight glass Removed and cleaned low water cut off Flushed pigtail Sight glass show corrosion, nuts show corrosion, rubber gaskets show deterioration Drain boiler tank valve hard to open/close. Reset water feeder to 000 Checked heat via infrared - Trevor Doughter room is not heating Dining room not heating Customer did not go with repair
Birmingham, MI 48009
Devin P.
Devin P. Checked in
Replace evaporator Replace filter drier Recharge to specification
Birmingham, MI 48009